FA-430 HEPA Compact Fume Extraction Unit

£756.52
Excluding VAT
Available for Order**
SKU
HFA430-13
  • Compact and Quiet Fume Extraction Unit.
  • HEPA filter (High Efficiency Particulate Air Filter)
  • Filters out 99.97% of particles greater than 0.3μm
  • Recommended for quiet laboratory and office
  • Duct Set NOT included, please purchase separatel
click to enlarge image

FA-430 Compact Fume Extraction Unit

The Hakko FA-430 Smoke and Fume Extractor is specially designed for use in the electronics soldering process by extracting the contaminated air directly at the source. The three stage filtering system returns purified air to the area using a HEPA (High Efficiency Particulate Air filter).

It’s light, compact design and quiet operation make it ideal for laboratories or office spaces providing powerful fume extraction where full scale extraction is not an option.

Optional parts are available to negate the effect of air conditioning on the extraction airflow to further improve efficiency.

 

HEPA filter captures 99.97% of particles greater than 0.3μm

FA-430 provides excellent filtering efficiency, 99.97% of particles greater than 0.3μm, by HEPA filter.

 

A1572 Pre Filter for the FA-430

Filter replacement notification function ensures excellent trapping efficiency can be maintained at all times

No matter how sophisticated a fume extractor is, if the filter is not replaced at the right time, it will not be able to give maximum performance. The HAKKO FA-430 detects the number of fan rotation and notifies the operator of the appropriate time to replace the filter, guaranteeing a comfortable working environment.

  • Pre-filter
    When the pre-filter is 80% clogged or has been used for 200 hours, the orange indicator flashes on and off.

 

  • Main filter
    When the 10th pre-filter needs replacing, the orange and red lamps flash on and off.

Quiet operation and powerful suction.

Exhaust noise has been reduced without sacrificing suction performance by the addition of a silencer unit to the exhaust outlet to ensure smooth air outflow. A high-performance motor with 1,500 Pa of static pressure provides powerful suction and quiet operation.

 

Noise level dB (A)

Air volume m3/min

HIGH

53

4.7

MEDIUM

50

3.7

LOW

44

2.8

*Values measured when the unit was used with a 60 Hz power supply.

Catch harmful smoke with freestanding ducts and adjustable air volume to suit your working environment

Is your smoke absorber affected by air conditioning? Are you fed up with having to re-adjust ducts after every line change? The HAKKO FA-430 fume extractor is the answer to your problems.

Airflow adjustment

Three airflow modes are available: High, Medium, and Low. Significantly improve your working environment by using an airflow volume that suits the worksite and the job.

  • Low mode: Not easily affected by the surrounding environment. For use in small, quiet locations. (For when low-noise operation is a priority.)
  • Medium mode: For normal use.
  • High mode: For use in locations that are significantly affected by the surrounding environment. (For when suction performance is a priority.)

What do you mean by "surrounding environment"?

Smoke flows in unexpected directions due to a variety of factors; not just because of the influence of air conditioning. High mode is recommended if your worksite is situated near a doorway, in a spot where people continuously pass by, near the exhaust outlet of a large machine, or in a similar location. It is possible to use low mode in laboratories and other places where these kinds of influences are limited.

Freestanding ducts

Ducts can be bent or lengthened as desired and maintain their shape after adjustment, letting you place them exactly where suction is needed. Say goodbye forever to ducts that are long, heavy, and hard-to-handle.

 

Length

Weight

Duct for HAKKO FA-430

1.2m

0.6kg

 

Photo above:
Bends and stretches freely for perfect placement!

Photo on left:
Lightweight and compact, the HAKKO FA-430 weighs only 7.5 kg. Built-in handles allow the fume extractor to be moved easily, facilitating line changeovers.

*HAKKO FA-430 weighs 35% less than previous models

 

If the duct is mounted at an angle above the workpiece, it is easily affected by air conditioning

If the duct is mounted directly above, it can be difficult to see the workpiece

Duct is mounted on the worktable to provide excellent suction performance

Usage/Application

Proper installation of the pre-filter

  • Proper installation
    Install the pre-filter inside the frame of the main filter as shown in image 1.
    Be sure to check that there are no gaps at the corners as shown in image 2.
  • Improper installation
    If the pre-filter is not installed properly as shown in images 3 and 4, the main filter will degrade its original performance quickly.

Note: Some processes may involve the use of highly corrosive substances and are not recommended for use with the FA-430.

Packing List

Model No.

Packing List

FA-430

  • Main unit,
  • Power cord (B2425)
  • Cap (B3619)
  • Main filter (A1573)
  • Pre-filters (x10) (A1572)
  • Instruction manual

 

Duct set (C1571/C1572) is NOT included in FA-430 unit. Please purchase Duct set(s) when you order FA-430 unit.

Model No.

Packing List

 

Duct Set C1571
(With rectangular nozzle)

  • Duct (Φ 55mm x 1.2m)
  • Adapter (B3620)
  • Rectangular nozzle (B3622)
  • Net (B3625)
  • Instruction manual

Buy

Duct Set C1572
(With round nozzle)

  • Duct (Φ 55mm x 1.2m)
  • Adapter, (B3620)
  • Round nozzle (B3623)
  • Net, (B3625)
  • Instruction manual

Buy

 

Specifications

Model No.

FA-430

Power consumption

110W

Noise level

50dB (MEDIUM mode)

Maximum suction capacity

with single duct : MAX. 4.1m3/min. (145cfm)
with two ducts : MAX. 4.7m3/min. (167cfm)

Filtering efficiency

99.97% 0.3µm (LOW, MEDIUM mode)
99.96% 0.3µm (HIGH mode)

Static pressure

1,500Pa

Duct set (sold separately)

Length of duct : Φ55mm×1.2m (ESD SAFE)

Dimensions

330(W)×366(H)×343(D)mm

Weight

7.5kg

* Filtering efficiency is an initial value of collection efficiency based on counting method for airborne dust collected by a single plate of filter (unfolded).
* Noise level is measured at a distance of 1 m from the face of unit in an anechoic room.
* Net in duct sets are not protected against electrostatic discharge.

Optional / Recommended Extras

Images

Part Number

Description

Availability

 photo:FH800-03SV

C1571

Duct set with rectangular type nozzle

Buy

photo:FH800-03SV

C1572

Duct set with round type nozzle

Buy

photo:FH800-03SV

B3642

Duct Φ55mm×1.2m

Buy

photo:FH800-03SV

B3620

Adapter

Buy

photo:FH800-03SV

B3621

Adapter 3 inch

Buy

photo:FH800-03SV

B3622

Nozzle/rectangular type

Buy

photo:FH800-03SV

B3623

Nozzle/round type

Buy

photo:FH800-03SV

B3625

Net (qty 5)

Buy

photo:FH800-03SV

B2410

Duct/2m Φ75mm×2m

Buy

photo:FH800-03SV

B2416

Duct band (qty 2)

Buy

photo:FH800-03SV

B2418

Bench top plenum/clear

Buy

-When using an independent duct

Part No.

Part Name

Notes

 

B3642

Duct

ø55 x 1.2 m
photo:FH800-03SV

Buy

B3620

Adapter

For attaching duct to main unit.
photo:FH800-03SV

Buy


-Choose from one of 2 types of nozzles for the independent duct.

Part No.

Part Name

Notes

 

B3622

Nozzle, rectangular

For absorbing smoke from the side.

photo:FH800-03SV

Buy

B3623

Nozzle, round

For absorbing smoke from above

photo:FH800-03SV

Buy

B3625

Net (5 per pack)

For preventing contaminants from being absorbed.
(Mesh dimensions: Approx. 10 mm × 10 mm)

photo:FH800-03SV

Buy

 

-When using a bench top hood

The benchtop hood detailed below requires the separate purchase of a different sized duct, duct band, and 3-inch adapter.

Part No.

Part Name

Notes

 

B2418

Benchtop hood

For stopping smoke from escaping upwards without being affected by air conditioning.

photo:FH800-03SV

*Requires ø75 duct, duct band (B2416), and 3-inch adapter (B3621).

Buy

B2410

Duct

Required when using benchtop hood.

photo:FH800-03SV

*ø75 x 2 m. Not freestanding.

Buy

B2416

Duct band

Required when using benchtop hood.

photo:FH800-03SV

Buy

B3621

Adapter (for 3-inch duct)

Required when using benchtop hood and ø75 duct.

photo:FH800-03SV

Buy

 

Replacement Parts

photo:FH800-03SV

 

Part No.

Name

 

photo:FH800-03SV

1. A1572

Pre-filter (qty 10)

Buy

photo:FH800-03SV

2. A1573

Main filter

Buy

photo:FH800-03SV

3. B3619

Cap

Buy

photo:FH800-03SV

4. B1486

Knob

 

photo:FH800-03SV

5. B2852

Power Switch

Buy

photo:FH800-03SV

6. B2425

Power Lead BS Plug

Buy